Summary
High Tension Substation 33kV 400-20000kVA is a compact, integrated transformer station designed for efficient urban and rural power distribution. Featuring high reliability, low installation workload, and short commissioning time, it combines HV/LV switchgear, transformer, and protection systems in one complete solution. Ideal for residential areas, factories, mines, and renewable energy projects, this modular substation ensures stable performance, easy mobility, and environmental adaptability with corrosion-resistant materials and customizable exterior design—perfect for modern smart grid and clean energy infrastructure applications.More
Specifications
Model:
SZ7,SZ9
Raled voltage(kV):
33
Rated capacity(kva):
400-20000
  • High Tension Substation 33kV 400-20000kVA Compact Integrated Transformer Station for Urban and Rural Power Distribution
  • High Tension Substation 33kV 400-20000kVA Compact Integrated Transformer Station for Urban and Rural Power Distribution

 YBW33KV Overview

YBW 35kV Combined type transformer substation is a kind of complete set product integrating voltage switch equipmentand transformer with LV distribution equipment. It is usually applied to civic architec-tures,

Residential districts,mid-size and small-size factories, mine and oil fields, used as tran-sformation and distribution equipment,with characteristics of strong completeness, compact struct-ure, high

Reliability, low on-site workload, shortinstallation period, movability, etc. In addition, its color and exterior can be changed appropriately to adaptto the surroundings and beautifythe environment,

It really is the ideal successor of current urban and ruralcivil engineering transformer substation, and also is a new type complete set equipment for urban network construction and reformation.


Substation series


YBW33KV Use environmental conditions

1. Altitude: W 1000m;

2. Ambient temperature: +40°C -25°C;

3. Relative humidity: Daily average W 95%, monthly average W 90%;

4. Abnormal severe vibration or impact;

5. Environment for installation: Indoors, no fire or explosion danger, no corrosive gas or dust, no sharp impact

Note: Please negotiate with us ifyour product is used beyond the range of above conditions.


YBW33KV Structural features

1. This transformer substation is made up of HV swich compartment, LV switch compartment, relay protection compartment and transformer compartment. Enclosures of HV switch compartment, LV switch compartment and relay protection compartment can be made of aluminum alloy plate, steel plate of composite plate. Aluminum alloy plate is anodic oxidation treated to strengthen its corrosion stability. Steel plate and steel structured parts are all phosphating treated, and the composite plate is featured with vivid appearance, heat insulation and fire retardation. The transformer compartm-ent is arranged with safeguard protecting net but not enclosed enclosure, which notonly gua-rantees better thermal diffusivity, but also is able to insure person and equipment against accident.

2. HV switch compartment The HV switch compartment can be mounted with JYNI-35, KYN10-35 switchgear or 35KV load switch. Aerial cable type is available formounting 35KV inletand outlet wire.

3. LV switch compartment

? When it is 10KV at LV side, the LV switch compartment can be mounted with XGN2-10, KZNI-12 and KYNI-12 swichgear, HXGNII- 10F, HXGN26-10(F) Ring mainunit

? When it is 0.4KV at LV side, the LV switch compartment (no preparation of LV switchgear in consideration of space saving) can be mounted with DW15T series, MEseries, M series and F series frame type circuit breaker as well as DZ20 series, CM series, H series and S series molded case air circuit breaker.

4. Power-off protection compartment The power-off protection compartment is mounted with AC panel, DC panel, signal panel, protection pandel, motion control panel(RTU), carrier wave machine panel or optical fiber termination set.

Note: This transformer substation can adopt general relay protection, also microcomputer-based integreted automatic control system is available on request

5. Refer to the diagram for plan layout and vertical plane layout of transformer substation of 35KV.


Download
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Fill out the form below to make an inquiry
Company*
Country/Region*
FirstName*
LastName*
Business Email*
Whatsapp/Phone*
Your Request*
Verification code*
We needs the contact information you provide to us to contact you about our products and services.
If your supplier does not respond within 24 hours, we will connect you with three to five qualified alternative suppliers.
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.